Recent Movies

Temperature Control Steam Traps Miyawaki



Temperature Control Steam Traps are bimetallic steam traps the which do not follow the steam saturation curve. The discharge temperature can be adjusted manually, the which allow Reviews These steam traps to adopt to a wide range of applications, where optional undercooling is possible and where sensible heat savings and flash steam reduction are desirable. Reviews These steam traps are perfectly fitted for reducing the steam consumption at the main steam lines and steam tracing Tus guaranteeing a high degree of energy savings.

Miyawaki Steam Temperature Trap




Miyawaki Temperature Steam Trap

Curve 1 shows the trap's maximum capacity when discharging cold condensate at a temperature of 20 ° C (68 ° F). Curve 2 shows the trap's maximum capacity when discharging hot condensate at a temperature of 10 ° C (18 ° F) below the adjusted temperature of the trap. Standard factory settings: 100 ° C at 1.0 MPa (212 ° F at 145 psig) Settings may Differ in various regions. For more information please contact us.

Spesial Dimensions Miyawaki Steam Trap



Special Dimensions Miyawaki Steam Trap

Special face-to-face dimensions available. Curve 1 shows the trap's maximum capacity when discharging cold condensate at a temperature of 20 ° C (68 ° F). Curve 2 shows the trap's maximum capacity when discharging hot condensate at a temperature of 10 ° C (18 ° F) below the adjusted temperature of the trap.

Stem Trap With Fleng SV






Stem Trap With Fleng SV

Thermodynamic steam traps, operate on the basis of the Bernoulli principle, Depending on the relationship between the velocity and the pressure exerted by the condensate and steam inside the steam trap. They have only one moving part - the disc. Due to Reviews their compact design and cost effectiveness, Instant confirmation thermodynamic steam traps are used in applications where the condensate must be removed Immediately from steam lines and steam equipment. They discharge the condensate
near the saturation temperature. The traps may operate-up to a back pressure of 80% of the inlet pressure, but for smooth operation it is recommended that the back pressure does not exceed 50% of the inlet pressure. Thermodynamic steam traps discharge the condensate intermittently. All steam traps are equipped with a hardened stainless steel disc and seat. After the lapping process all disc surfaces are controlled individually before releasing them for use in steam traps. Reviews These features and very high and severe quality standards for the whole production process give Miyawaki's thermodynamic steam traps a long and reliable service life. Types S31N Ductile Cast Iron Steam Traps with replaceable internals SC, SF Cast Iron Steam Traps for high capacity SC31 Stainless Steel Steam Traps with replaceable internals SD1, SU2N, SU2H Stainless Steel Steam Traps for low to high pressure applications S55N, S61N, S62N Forged Steel Steam Traps for high pressure applications SV Steam Traps with inbuilt bypass SL3 Compact, very small trap for low capacity applications Features - Immediate discharge of condensate:

- Insensitive to waterhammer, superheated steam and freezing
- Most types Contain a bimetal ring the which improves the ability of the trap to discharge water
and cold condensate quickly intervening at start-up and prevents locking of water during times of operation
- Can be installed in any position
- In case of danger of the water available locking discs special
- All traps equipped with additional cover for reduced frequency of cycling and energy savings
- All traps with inbuilt strainers (except SL3)
- Easy maintenance

Suitable for light to medium condensate loads: steam tracing, steam playing drips, small heat exchangers, unit heaters, sterilizers and many other applications in the petrochemical, chemical, textile, food, pharmaceutical and further industries. Series SV Thermodynamic steam traps with inbuilt bypass are designed for special applications in the food, pharmaceutical or other industries or for laundry applications where costs and space must be saved.

Inverted Bucket Trap – Low Pressure / Large Capacity Miyawaki Seri ER




Inverted Bucket Trap - Low Pressure / Large Capacity Series ER Miyawaki

Inverted Bucket Steam Traps belong to the family of mechanical traps. They, operate on the difference in density between steam and water. Miyawaki offers a very wide range of inverted bucket steam traps for small up to large condensate loads. Inverted bucket steam traps discharge the condensate intermittently.

types
ES: Cast Iron Inverted Bucket Steam Traps for small up to medium condensate loads
ESU: Stainless Steel Inverted Bucket Steam Traps for small up to medium condensate loads
ER: Cast Iron Inverted Bucket Steam Traps for medium up to high condensate loads
ESH, ER25: Cast Steel Inverted Bucket Steam Traps for high pressure and small up to high condensate loads

Inverted Bucket Trap – Low Pressure Es Stem trap Miyawaki




Inverted Bucket Trap - Low Pressure Ice Stem trap

Inverted Bucket Steam Traps belong to the family of mechanical traps. They, operate on the difference in density between steam and water. Miyawaki offers a very wide range of inverted bucket steam traps for small up to large condensate loads. Inverted bucket steam traps discharge the condensate intermittently.

types
ES: Cast Iron Inverted Bucket Steam Traps for small up to medium condensate loads
ESU: Stainless Steel Inverted Bucket Steam Traps for small up to medium condensate loads
ER: Cast Iron Inverted Bucket Steam Traps for medium up to high condensate loads
ESH, ER25: Cast Steel Inverted Bucket Steam Traps for high pressure and small up to high condensate loads

Inverted Bucket Trap – Low Pressure Stem Trap Miyawaki




Inverted Bucket Trap - Low Pressure Stem Trap Miyawaki


Inverted Bucket Steam Traps belong to the family of mechanical traps. They, operate on the difference in density between steam and water. Miyawaki offers a very wide range of inverted bucket steam traps for small up to large condensate loads. Inverted bucket steam traps discharge the condensate intermittently.

types
ES: Cast Iron Inverted Bucket Steam Traps for small up to medium condensate loads
ESU: Stainless Steel Inverted Bucket Steam Traps for small up to medium condensate loads
ER: Cast Iron Inverted Bucket Steam Traps for medium up to high condensate loads
ESH, ER25: Cast Steel Inverted Bucket Steam Traps for high pressure and small up to high condensate loads

 